TRANSFORMER BUSHINGS

For use in moderately polluted atmospheres 

12-17.5 kV, 24 kV, 36 kV, 1 kV3.6 kV 

TRANSFORMER BUSHING TRANSFORMER BUSHING TRANSFORMER BUSHING

TRANSFORMER BUSHINGS 12-17.5 kV

 

 LINE DIAGRAM - TRANSFORMER BUSHING 12-17.5 kV

LINE DIAGRAM - TRANSFORMER BUSHING 12-17.5 kV

LINE DIAGRAM - TRANSFORMER BUSHING 12-17.5 kV

LINE DIAGRAM - TRANSFORMER BUSHING 12-17.5 kV

LINE DIAGRAM - TRANSFORMER BUSHING 12-17.5 kV

LINE DIAGRAM - TRANSFORMER BUSHING 12-17.5 kV

 

STANDARD PARTICULARS
Product No.

BCPL

1101

BCPL

1102

BCPL

1103

BCPL

1104

Ratings

12 kV/

250 Amp

12 kV/400

630 Amp

12 kV/

1000 Amp

12 kV/

2000-3150 Amp

Power Frequency One minute

Dry, kVRms 50 50 50 50
WithstandVoltage

Wet, kVRms

45 45 45 45
Impulse Withstand Voltage, kVp 95 95 95 95

STANDARD SPECIFICATIONS : IS 3347 Part III/Sec 1& IS 2099 & IEC-233

TRANSFORMER BUSHINGS 24 kV

 LINE DIAGRAM - TRANSFORMER BUSHING 24 kV

LINE DIAGRAM - TRANSFORMER BUSHING 24 kV LINE DIAGRAM - TRANSFORMER BUSHING 24 kV

LINE DIAGRAM - TRANSFORMER BUSHING 24 kV

LINE DIAGRAM - TRANSFORMER BUSHING 24 kV LINE DIAGRAM - TRANSFORMER BUSHING 24 kV
STANDARD PARTICULARS
Product No. BCPL-2201 BCPL-2202 BCPL-2203 BCPL-2204
Ratings

24 kV/

250 Amp

24 kV/400

630 Amp

24 kV/

1000 Amp

24 kV/2000

3150 Amp

Dimensions A mm 145 155 175 190
B mm 150 160 180 200
C mm 155 165 185 210
D mm Min 32 39 58 74
E mm Max 111 128 163 183

Product Frequency One Minute

Withstand Voltage

Dry, kV 60 60 60 60
Wet, kV 55 55 55 55
Impulse Withstand Voltage, kVp 125 125 125 125

STANDARD SPECIFICATIONS : IS 3347 Part 4/Sec 1 & IS 2099 & IEC-233

TRANSFORMER BUSHINGS 36 kV

LINE DIAGRAM - TRANSFORMER BUSHING 36 kV

LINE DIAGRAM - TRANSFORMER BUSHING 36 kV

LINE DIAGRAM - TRANSFORMER BUSHING 36 kV

LINE DIAGRAM - TRANSFORMER BUSHING 36 kV

LINE DIAGRAM - TRANSFORMER BUSHING 36 kV

LINE DIAGRAM - TRANSFORMER BUSHING 36 kV

 

STANDARD PARTICULARS
Product No.

BCPL

3302

BCPL

3303

BCPL

3304

BCPL

3305

Ratings

36 kV/250

Amp

36 kV/400-

630 Amp

36 kV/1000

Amp

36 kV/2000-3150

Amp

Visible Discharge Voltage, kV 27 27 27 27

Power Frequency One Minute

Withstand Voltage

Dry kV 80 80 80 80
Wet kV 75 80 80 80
Impulse Withstand Voltage, kVp 180 180 180 180

STANDARD SPECIFICATIONS : IS 3347 Part V/Sec 1 & IS 2099 & IEC-233

TRANSFORMER BUSHINGS 1 kV

LINE DIAGRAM - TRANSFORMER BUSHING 1 kV

LINE DIAGRAM - TRANSFORMER BUSHING 1 kV

STANDARD PARTICULARS
Product No. BCPL-0101 BCPL-0102 BCPL-0103 BCPL-0104 BCPL-0105
Ratings 1.1 kV/250 Amp 1.1 kV/400,630 Amp 1.1 kV/1000 Amp 1.1 kV/2000 Amp 1.1 kV/3150 Amp
Part I II I II I II I II I II
Dimensions A mm 50 60 70 85 90 110 104 125 125 150
B mm min 14 20 22 28 32 37 44 51 50 61
C mm 70 30 80 30 85 35 85 35 85 35
D mm 45 50 55 70 55 90 55 104 55 125
E mm 27 26 43 41 53 46 66 64 86 80
F mm 34 30 49 46 67 57 82 70 100 90

Power

Frequency

Withstand

Voltage

Dry kV 12 - 12 - 12 - 12 - 12 -
Wet kV 10 - 10 - 10 - 10 - 10 -

STANDARD SPECIFICATIONS : IS 3347 Part 1/Sec 1 & IS 7421& IEC-233

TRANSFORMER BUSHINGS 3.6 kV

LINE DIAGRAM - TRANSFORMER BUSHING 3.6 kV

LINE DIAGRAM - TRANSFORMER BUSHING 3.6 kV

STANDARD PARTICULARS
Product No. BCPL-0304 BCPL-0305 BCPL-0301 BCPL-0302 BCPL-0303
Ratings 3.6 kV/250 Amp 3.6 kV/400, 630 Amp 3.6 kV/1000 Amp 3.6 kV/2000 Amp 3.6 kV/3150 Amp
Part I II I II I II I II I II
Dimensions A mm 75 70 90 85 110 110 125 125 145 150
B mm 32 60 47 70 65 90 80 105 100 125
C mm 32 40 47 46 65 57 80 70 10 0 90
D mm 37 26 43 41 53 46 66 64 86 80
E mm 14 20 22 28 32 37 44 51 50 61
F mm 60 - 70 - 90 - 105 - 125 -

Power

Frequency

Withstand

Voltage

Dry kV 21 - 21 - 21 - 21 - 21 -
Wet kV 21 - 21 - 21 - 21 - 21 -
Impulse Withstand Voltage, kVp 45 - 45 - 45 - 45 - 45 -

STANDARD SPECIFICATION : IS 3347 Part II/Sec 1 & 2099 & IEC - 233